HV Battery Junction Block Assembly
HV BATTERY JUNCTION BLOCK ASSEMBLY
| Item | Tester Connection | Condition | Specified Condition |
| SMRB Resistance |
M3-1 (CBI) - z33-1 (+) | Auxiliary battery voltage not applied between terminals e2-1 (SMRB) and e2-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals e2-1 (SMRB) and e2-3 (GND) | Below 1 Ω | ||
| e2-1 (SMRB) - e2-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω | |
| SMRG Resistance |
M4-1 (CEI) - A-1 (-) | Auxiliary battery voltage not applied between terminals e2-4 (SMRG) and e2-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals e2-4 (SMRG) and e2-3 (GND) | Below 1 Ω | ||
| e2-4 (SMRG) - e2-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω | |
| SMRP Resistance |
M4-1 (CEI) - A-1 (-) | Auxiliary battery voltage is not applied between terminals e2-2 (SMRP) and e2-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals e2-2 (SMRP) and e2-3 (GND) | 24.3 to 29.7 Ω | ||
| e2-2 (SMRP) - e2-3 (GND) | -40 to 80°C (-40 to 176°F) | 140 to 290 Ω |