LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2022 >> LS 500h AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - Diagnostic Codes (P060E - P107A) >> SFI System >> DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [10/2017 - 09/2018] >> Typical Malfunction Thresholds
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Malfunction Thresholds

CASE 1

Either of the following conditions 1 or 2 is met 2 data or more
1. One of the following conditions (a), (b) or (c) is met More than 3 times
(a) EEPROM communication timeout Occurred
(b) Permanent Fault Code Not stored
(c) Permanent Fault Code Not equal to commanded Fault Code
2. Storing processing is more than 0.393216 seconds Not completed
CASE 2

Either of the following conditions 1 or 2 is met 2 data or more
1. Either of the following conditions (a) or (b) is met More than 3 times
(a) EEPROM communication timeout Occurred
(b) Permanent Fault Code Stored
2. Clearing processing is more than 0.393216 seconds Not completed
CASE 3

Either of the following conditions is met 1 or 2
1. The following conditions (a) is met 2 data or more
(a) EEPROM communication timeout (more than 3 times) Occurred
2. Permanent Fault Code data (more than 10 times) Mismatch