| P0606-49 |
Plug-in Control Module Processor Internal Electronic Failure |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0606 |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P060B-49 |
Plug-in Control Module A/D Processing Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P060B |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P062F-44 |
Plug-in Control Module EEPROM Data Memory Failure |
Comes on |
Master Warning: Does not come on |
Plug-in Control |
A |
SAE Code: P062F |
Refer to DTC P062F-44: Plug-in Control Module EEPROM Data Memory Failure [08/2023 - ] |
| P0D2A-19 |
Hybrid/EV Battery Charger Input Current Sensor Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D2A |
Refer to DTC P0D2A-19: Hybrid/EV Battery Charger Input Current Sensor Circuit Current Above Threshold [08/2023 - ] |
| P0D38-12 |
Hybrid/EV Battery Charger Input Current Sensor Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D3B |
Refer to DTC P0D38-12: Hybrid/EV Battery Charger Input Current Sensor Circuit Short to Auxiliary Battery; DTC P0D38-14: Hybrid/EV Battery Charger Input Current Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P0D38-14 |
Hybrid/EV Battery Charger Input Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D3A |
Refer to DTC P0D38-12: Hybrid/EV Battery Charger Input Current Sensor Circuit Short to Auxiliary Battery; DTC P0D38-14: Hybrid/EV Battery Charger Input Current Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P0D38-28 |
Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D39 |
Refer to DTC P0D38-28: Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure [08/2023 - ] |
| P0D38-9E |
Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D39 |
Refer to DTC P0D38-9E: Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On [08/2023 - ] |
| P0D3D-16 |
Hybrid/EV Battery Charger Input Voltage Sensor for Control Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D3F |
Refer to DTC P0D3D-16: Hybrid/EV Battery Charger Input Voltage Sensor for Control Circuit Voltage Below Threshold; DTC P0D3D-17: Hybrid/EV Battery Charger Input Voltage Sensor for Control Circuit Voltage Above Threshold [08/2023 - ] |
| P0D3D-17 |
Hybrid/EV Battery Charger Input Voltage Sensor for Control Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D40 |
Refer to DTC P0D3D-16: Hybrid/EV Battery Charger Input Voltage Sensor for Control Circuit Voltage Below Threshold; DTC P0D3D-17: Hybrid/EV Battery Charger Input Voltage Sensor for Control Circuit Voltage Above Threshold [08/2023 - ] |
| P0D4C-12 |
Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P0D4F |
Refer to DTC P0D4C-12: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Auxiliary Battery [08/2023 - ] |
| P0D4C-14 |
Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P0D4E |
Refer to DTC P0D4C-14: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P0D56-11 |
Charging Connector Proximity Detection Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D58 |
Refer to DTC P0D56-11: Charging Connector Proximity Detection Circuit Short to Ground [08/2023 - ] |
| P0D56-15 |
Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D59 |
Refer to DTC P0D56-15: Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open [08/2023 - ] |
| P0D5C-00 |
Charger Input/Output Power Difference High |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D5C |
Refer to DTC P0D5C-00: Charger Input/Output Power Difference High [08/2023 - ] |
| P0D99-11 |
Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit Low Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D9B |
Refer to DTC P0D99-11: Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit Low Circuit Short to Ground; DTC P0D99-15: Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit High Circuit Short to Auxiliary Battery or Open [08/2023 - ] |
| P0D99-15 |
Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit High Circuit Short to Auxiliary Battery or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D9C |
Refer to DTC P0D99-11: Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit Low Circuit Short to Ground; DTC P0D99-15: Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit High Circuit Short to Auxiliary Battery or Open [08/2023 - ] |
| P0E5E-49 |
Hybrid/EV Battery Charger Control Module Internal Electronic Failure |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0E5E |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P0E5E-87 |
Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0E5E |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P0E61-49 |
Hybrid/EV Battery Charger Enable Circuit Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0E64 |
Refer to DTC P0E61-49: Hybrid/EV Battery Charger Enable Circuit Internal Electronic Failure [08/2023 - ] |
| P0E89-19 |
Charger "B" Input Current Too High Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0E89 |
Refer to DTC P0E89-19: Charger "B" Input Current Too High Circuit Current Above Threshold [08/2023 - ] |
| P0E8A-12 |
Charger "B" Input Current Sensor Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P2D84 |
Refer to DTC P0E8A-12: Charger "B" Input Current Sensor Circuit Short to Auxiliary Battery; DTC P0E8A-14: Charger "B" Input Current Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P0E8A-14 |
Charger "B" Input Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P2D83 |
Refer to DTC P0E8A-12: Charger "B" Input Current Sensor Circuit Short to Auxiliary Battery; DTC P0E8A-14: Charger "B" Input Current Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P0E8A-28 |
Charger "B" Input Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P2D85 |
Refer to DTC P0E8A-28: Charger "B" Input Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [08/2023 - ] |
| P0E8A-9E |
Charger "B" Input Current Sensor Circuit Stuck On |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0E8A |
Refer to DTC P0E8A-9E: Charger "B" Input Current Sensor Circuit Stuck On; DTC P1BB5-9E: Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Overcurrent Detection Circuit Stuck On [08/2023 - ] |
| P0E8B-16 |
Charger "B" Input Voltage Sensor Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BC8 |
Refer to DTC P0E8B-16: Charger "B" Input Voltage Sensor Circuit Voltage Below Threshold; DTC P0E8B-17: Charger "B" Input Voltage Sensor Circuit Voltage Above Threshold [08/2023 - ] |
| P0E8B-17 |
Charger "B" Input Voltage Sensor Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BC9 |
Refer to DTC P0E8B-16: Charger "B" Input Voltage Sensor Circuit Voltage Below Threshold; DTC P0E8B-17: Charger "B" Input Voltage Sensor Circuit Voltage Above Threshold [08/2023 - ] |
| P0EE7-11 |
Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit Low Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0EE9 |
Refer to DTC P0EE7-11: Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit Low Circuit Short to Ground; DTC P0EE7-15: Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit High Circuit Short to Auxiliary Battery or Open [08/2023 - ] |
| P0EE7-15 |
Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit High Circuit Short to Auxiliary Battery or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0EEA |
Refer to DTC P0EE7-11: Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit Low Circuit Short to Ground; DTC P0EE7-15: Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit High Circuit Short to Auxiliary Battery or Open [08/2023 - ] |
| P0EF7-16 |
Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0EF9 |
Refer to DTC P0EF7-16: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold; DTC P0EF7-17: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold [08/2023 - ] |
| P0EF7-17 |
Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0EFA |
Refer to DTC P0EF7-16: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold; DTC P0EF7-17: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold [08/2023 - ] |
| P0EF7-28 |
Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0EF8 |
Refer to DTC P0EF7-28: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure [08/2023 - ] |
| P1A9F-49 |
Charger Control Module "B" A/D Processing Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1A9F |
Refer to DTC P1A9F-49: Charger Control Module "B" A/D Processing Internal Electronic Failure; DTC P1AAE-1C: Charger Control Module "B" Power Supply (Plus) Circuit Voltage Out of Range; DTC P1AAF-1C: Charger Control Module "B" Power Supply (Minus) Circuit Voltage Out of Range; DTC P1AC9-1C: Charger Control Module "B" Power Supply (Offset) Circuit Voltage Out of Range; DTC P2D78-49: Charger Control Module "B" Processor Performance Internal Electronic Failure; DTC P2D78-87: Charger Control Module "B" Processor Performance Missing Message [08/2023 - ] |
| P1AAE-1C |
Charger Control Module "B" Power Supply (Plus) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1AAE |
Refer to DTC P1A9F-49: Charger Control Module "B" A/D Processing Internal Electronic Failure; DTC P1AAE-1C: Charger Control Module "B" Power Supply (Plus) Circuit Voltage Out of Range; DTC P1AAF-1C: Charger Control Module "B" Power Supply (Minus) Circuit Voltage Out of Range; DTC P1AC9-1C: Charger Control Module "B" Power Supply (Offset) Circuit Voltage Out of Range; DTC P2D78-49: Charger Control Module "B" Processor Performance Internal Electronic Failure; DTC P2D78-87: Charger Control Module "B" Processor Performance Missing Message [08/2023 - ] |
| P1AAF-1C |
Charger Control Module "B" Power Supply (Minus) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1AAF |
Refer to DTC P1A9F-49: Charger Control Module "B" A/D Processing Internal Electronic Failure; DTC P1AAE-1C: Charger Control Module "B" Power Supply (Plus) Circuit Voltage Out of Range; DTC P1AAF-1C: Charger Control Module "B" Power Supply (Minus) Circuit Voltage Out of Range; DTC P1AC9-1C: Charger Control Module "B" Power Supply (Offset) Circuit Voltage Out of Range; DTC P2D78-49: Charger Control Module "B" Processor Performance Internal Electronic Failure; DTC P2D78-87: Charger Control Module "B" Processor Performance Missing Message [08/2023 - ] |
| P1AC9-1C |
Charger Control Module "B" Power Supply (Offset) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1AC9 |
Refer to DTC P1A9F-49: Charger Control Module "B" A/D Processing Internal Electronic Failure; DTC P1AAE-1C: Charger Control Module "B" Power Supply (Plus) Circuit Voltage Out of Range; DTC P1AAF-1C: Charger Control Module "B" Power Supply (Minus) Circuit Voltage Out of Range; DTC P1AC9-1C: Charger Control Module "B" Power Supply (Offset) Circuit Voltage Out of Range; DTC P2D78-49: Charger Control Module "B" Processor Performance Internal Electronic Failure; DTC P2D78-87: Charger Control Module "B" Processor Performance Missing Message [08/2023 - ] |
| P1BA8-49 |
Charger "B" Enable Circuit Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BAB |
Refer to DTC P1BA8-49: Charger "B" Enable Circuit Internal Electronic Failure [08/2023 - ] |
| P1BB0-12 |
Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BB3 |
Refer to DTC P1BB0-12: Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery; DTC P1BB0-14: Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open [08/2023 - ] |
| P1BB0-14 |
Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BB2 |
Refer to DTC P1BB0-12: Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery; DTC P1BB0-14: Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open [08/2023 - ] |
| P1BB0-16 |
Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BB1 |
Refer to DTC P1BB0-16: Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Voltage Below Threshold [08/2023 - ] |
| P1BB0-9E |
Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BB0 |
Refer to DTC P1BB0-9E: Charger "B" Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On [08/2023 - ] |
| P1BB5-12 |
Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BB8 |
Refer to DTC P1BB5-12: Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery; DTC P1BB5-14: Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open [08/2023 - ] |
| P1BB5-14 |
Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BB7 |
Refer to DTC P1BB5-12: Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery; DTC P1BB5-14: Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open [08/2023 - ] |
| P1BB5-28 |
Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BB6 |
Refer to DTC P1BB5-28: Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Signal Bias Level Out of Range / Zero Adjustment Failure [08/2023 - ] |
| P1BB5-9E |
Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Overcurrent Detection Circuit Stuck On |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BB5 |
Refer to DTC P0E8A-9E: Charger "B" Input Current Sensor Circuit Stuck On; DTC P1BB5-9E: Charger "B" Current Sensor after Boosting by PFC Boosting Circuit Overcurrent Detection Circuit Stuck On [08/2023 - ] |
| P1BBA-17 |
Charger "B" Voltage after Boosting by PFC Boosting Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BBA |
Refer to DTC P1BBA-17: Charger "B" Voltage after Boosting by PFC Boosting Circuit Voltage Above Threshold [08/2023 - ] |
| P1BBB-19 |
Charger "B" Current after Boosting by PFC Boosting Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BBB |
Refer to DTC P1BBB-19: Charger "B" Current after Boosting by PFC Boosting Circuit Current Above Threshold [08/2023 - ] |
| P1BBC-12 |
Charger "B" PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BBF |
Refer to DTC P1BBC-12: Charger "B" PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery; DTC P1BBC-14: Charger "B" PFC Inverter Temperature Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P1BBC-14 |
Charger "B" PFC Inverter Temperature Sensor Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BBE |
Refer to DTC P1BBC-12: Charger "B" PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery; DTC P1BBC-14: Charger "B" PFC Inverter Temperature Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P1BC1-12 |
Charger "B" DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BC4 |
Refer to DTC P1BC1-12: Charger "B" DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1BC1-14: Charger "B" DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [08/2023 - ] |
| P1BC1-14 |
Charger "B" DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BC3 |
Refer to DTC P1BC1-12: Charger "B" DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1BC1-14: Charger "B" DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [08/2023 - ] |
| P1BC6-62 |
Charger "B" PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BC6 |
Refer to DTC P1BC6-62: Charger "B" PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure [08/2023 - ] |
| P1BCB-16 |
Charger "B" Input Voltage Sensor "B" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BCD |
Refer to DTC P1BCB-16: Charger "B" Input Voltage Sensor "B" Circuit Voltage Below Threshold; DTC P1BCB-17: Charger "B" Input Voltage Sensor "B" Circuit Voltage Above Threshold [08/2023 - ] |
| P1BCB-17 |
Charger "B" Input Voltage Sensor "B" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BCE |
Refer to DTC P1BCB-16: Charger "B" Input Voltage Sensor "B" Circuit Voltage Below Threshold; DTC P1BCB-17: Charger "B" Input Voltage Sensor "B" Circuit Voltage Above Threshold [08/2023 - ] |
| P1BD0-62 |
Charger "B" Input Voltage Sensor "A" / "B" Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BD0 |
Refer to DTC P1BD0-62: Charger "B" Input Voltage Sensor "A" / "B" Signal Compare Failure [08/2023 - ] |
| P1BD1-17 |
Charger "B" Hybrid/EV Battery Input Voltage Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P1BD1 |
Refer to DTC P1BD1-17: Charger "B" Hybrid/EV Battery Input Voltage Circuit Voltage Above Threshold [08/2023 - ] |
| P1BD2-00 |
Charger "B" Input/Output Power Difference High |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BD2 |
Refer to DTC P1BD2-00: Charger "B" Input/Output Power Difference High [08/2023 - ] |
| P1BD3-00 |
Charger "B" PFC Boosting Circuit Malfunction |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BD2 |
Refer to DTC P1BD3-00: Charger "B" PFC Boosting Circuit Malfunction [08/2023 - ] |
| P1BD4-00 |
Charger "B" DC/DC Converter Malfunction (for Charging) |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BD2 |
Refer to DTC P1BD4-00: Charger "B" DC/DC Converter Malfunction (for Charging) [08/2023 - ] |
| P1BD5-00 |
Charger "B" Pre-charging Malfunction |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BD2 |
Refer to DTC P1BD5-00: Charger "B" Pre-charging Malfunction [08/2023 - ] |
| P1BD6-00 |
Charger "B" Charging Power Low |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BD2 |
Refer to DTC P1BD6-00: Charger "B" Charging Power Low [08/2023 - ] |
| P1BD7-00 |
Charger "B" Charging Power High |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BD2 |
Refer to DTC P1BD7-00: Charger "B" Charging Power High [08/2023 - ] |
| P1BD8-12 |
Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BDB |
Refer to DTC P1BD8-12: Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Auxiliary Battery; DTC P1BD8-14: Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Ground or Open [08/2023 - ] |
| P1BD8-14 |
Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BDA |
Refer to DTC P1BD8-12: Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Auxiliary Battery; DTC P1BD8-14: Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Ground or Open [08/2023 - ] |
| P1BDC-12 |
Charger "B" Input Current Sensor "B" Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BDF |
Refer to DTC P1BDC-12: Charger "B" Input Current Sensor "B" Circuit Short to Auxiliary Battery; DTC P1BDC-14: Charger "B" Input Current Sensor "B" Circuit Short to Ground or Open [08/2023 - ] |
| P1BDC-14 |
Charger "B" Input Current Sensor "B" Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1BDE |
Refer to DTC P1BDC-12: Charger "B" Input Current Sensor "B" Circuit Short to Auxiliary Battery; DTC P1BDC-14: Charger "B" Input Current Sensor "B" Circuit Short to Ground or Open [08/2023 - ] |
| P1BF8-62 |
Hybrid/EV Battery Charger Coupler Temperature Sensor "A"/"B" Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P1BF8 |
Refer to DTC P1BF8-62: Hybrid/EV Battery Charger Coupler Temperature Sensor "A"/"B" Signal Compare Failure [08/2023 - ] |
| P1C00-12 |
Voltage Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C03 |
Refer to DTC P1C00-12: Voltage Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery; DTC P1C00-14: Voltage Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open [08/2023 - ] |
| P1C00-14 |
Voltage Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C02 |
Refer to DTC P1C00-12: Voltage Sensor after Boosting by PFC Boosting Circuit Short to Auxiliary Battery; DTC P1C00-14: Voltage Sensor after Boosting by PFC Boosting Circuit Short to Ground or Open [08/2023 - ] |
| P1C00-16 |
Voltage Sensor after Boosting by PFC Boosting Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C01 |
Refer to DTC P1C00-16: Voltage Sensor after Boosting by PFC Boosting Circuit Voltage Below Threshold [08/2023 - ] |
| P1C00-9E |
Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C00 |
Refer to DTC P1C00-9E: Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On [08/2023 - ] |
| P1C05-12 |
PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C08 |
Refer to DTC P1C05-12: PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery; DTC P1C05-14: PFC Inverter Temperature Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P1C05-14 |
PFC Inverter Temperature Sensor Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C07 |
Refer to DTC P1C05-12: PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery; DTC P1C05-14: PFC Inverter Temperature Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P1C0A-12 |
DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C0D |
Refer to DTC P1C0A-12: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1C0A-14: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [08/2023 - ] |
| P1C0A-14 |
DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C0C |
Refer to DTC P1C0A-12: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1C0A-14: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [08/2023 - ] |
| P1C0F-96 |
AC Inverter Signal Line Component Internal Failure |
Does not come on |
Master Warning: Does not come on |
Plug-in Control |
B |
SAE Code: P1C0F |
Refer to DTC P1C0F-96: AC Inverter Signal Line Component Internal Failure [08/2023 - ] |
| P1C10-12 |
Current after Boosting by PFC Boosting Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C13 |
Refer to DTC P1C10-12: Current after Boosting by PFC Boosting Circuit Short to Auxiliary Battery; DTC P1C10-14: Current after Boosting by PFC Boosting Circuit Short to Ground or Open [08/2023 - ] |
| P1C10-14 |
Current after Boosting by PFC Boosting Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C12 |
Refer to DTC P1C10-12: Current after Boosting by PFC Boosting Circuit Short to Auxiliary Battery; DTC P1C10-14: Current after Boosting by PFC Boosting Circuit Short to Ground or Open [08/2023 - ] |
| P1C10-28 |
Current after Boosting by PFC Boosting Circuit Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C11 |
Refer to DTC P1C10-28: Current after Boosting by PFC Boosting Circuit Signal Bias Level Out of Range / Zero Adjustment Failure [08/2023 - ] |
| P1C10-9E |
Current after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C10 |
Refer to DTC P1C10-9E: Current after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On [08/2023 - ] |
| P1C1B-00 |
PFC Boosting Circuit Malfunction |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D5C |
Refer to DTC P1C1B-00: PFC Boosting Circuit Malfunction [08/2023 - ] |
| P1C1C-00 |
DC/DC Converter Malfunction (for Charging) |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D5C |
Refer to DTC P1C1C-00: DC/DC Converter Malfunction (for Charging) [08/2023 - ] |
| P1C1D-00 |
Charging Power Low |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D5C |
Refer to DTC P1C1D-00: Charging Power Low [08/2023 - ] |
| P1C1E-00 |
Charging Power High |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D5C |
Refer to DTC P1C1E-00: Charging Power High [08/2023 - ] |
| P1C1F-49 |
Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C1F |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P1C25-62 |
PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C25 |
Refer to DTC P1C25-62: PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure [08/2023 - ] |
| P1C26-17 |
Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P1C26 |
Refer to DTC P1C26-17: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold [08/2023 - ] |
| P1C27-17 |
Voltage Sensor after Boosting by PFC Boosting Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C27 |
Refer to DTC P1C27-17: Voltage Sensor after Boosting by PFC Boosting Circuit Voltage Above Threshold [08/2023 - ] |
| P1C28-19 |
Current after Boosting by PFC Boosting Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1C28 |
Refer to DTC P1C28-19: Current after Boosting by PFC Boosting Circuit Current Above Threshold [08/2023 - ] |
| P1CA4-00 |
Charger Pre-charging Malfunction |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P0D5C |
Refer to DTC P1CA4-00: Charger Pre-charging Malfunction [08/2023 - ] |
| P1CCD-96 |
Sub DC/DC Converter (for Charging) Component Internal Failure |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P1CCD |
Refer to DTC P1CCD-96: Sub DC/DC Converter (for Charging) Component Internal Failure [08/2023 - ] |
| P1CCD-9E |
Sub DC/DC Converter (for Charging) Stuck On |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1CCD |
Refer to DTC P1CCD-9E: Sub DC/DC Converter (for Charging) Stuck On [08/2023 - ] |
| P1CCD-9F |
Sub DC/DC Converter (for Charging) Stuck Off |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1CCD |
Refer to DTC P1CCD-9F: Sub DC/DC Converter (for Charging) Stuck Off [08/2023 - ] |
| P1CCE-12 |
Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1CD1 |
Refer to DTC P1CCE-12: Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1CCE-14: Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [08/2023 - ] |
| P1CCE-14 |
Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1CD0 |
Refer to DTC P1CCE-12: Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1CCE-14: Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [08/2023 - ] |
| P1CCE-1C |
Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1CCF |
Refer to DTC P1CCE-1C: Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Voltage Out of Range [08/2023 - ] |
| P1CE6-11 |
AC Inverter Status Signal Circuit Short to Ground |
Does not come on |
Master Warning: Does not come on |
Plug-in Control |
A |
SAE Code: P1CE7 |
Refer to DTC P1CE6-11: AC Inverter Status Signal Circuit Short to Ground; DTC P1CE6-15: AC Inverter Status Signal Circuit Short to Auxiliary Battery or Open [08/2023 - ] |
| P1CE6-15 |
AC Inverter Status Signal Circuit Short to Auxiliary Battery or Open |
Does not come on |
Master Warning: Does not come on |
Plug-in Control |
A |
SAE Code: P1CE8 |
Refer to DTC P1CE6-11: AC Inverter Status Signal Circuit Short to Ground; DTC P1CE6-15: AC Inverter Status Signal Circuit Short to Auxiliary Battery or Open [08/2023 - ] |
| P1CE9-31 |
Charger Cooling Fan Revolution Signal No Signal |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P1CEB |
Refer to DTC P1CE9-31: Charger Cooling Fan Revolution Signal No Signal; DTC P1CE9-96: Charger Cooling Fan Revolution Signal Component Internal Failure [08/2023 - ] |
| P1CE9-96 |
Charger Cooling Fan Revolution Signal Component Internal Failure |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P1CEA |
Refer to DTC P1CE9-31: Charger Cooling Fan Revolution Signal No Signal; DTC P1CE9-96: Charger Cooling Fan Revolution Signal Component Internal Failure [08/2023 - ] |
| P1CED-1C |
Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1CED |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P1CF0-1C |
Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1CF0 |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P1CF3-1C |
Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P1CF3 |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P1F24-12 |
Charger "B" Hybrid/EV Battery Input Voltage Sensor Circuit Short to Auxiliary Battery |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P1F27 |
Refer to DTC P1F24-12: Charger "B" Hybrid/EV Battery Input Voltage Sensor Circuit Short to Auxiliary Battery [08/2023 - ] |
| P1F24-14 |
Charger "B" Hybrid/EV Battery Input Voltage Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: P1F26 |
Refer to DTC P1F24-14: Charger "B" Hybrid/EV Battery Input Voltage Sensor Circuit Short to Ground or Open [08/2023 - ] |
| P2D78-49 |
Charger Control Module "B" Processor Performance Internal Electronic Failure |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P2D78 |
Refer to DTC P1A9F-49: Charger Control Module "B" A/D Processing Internal Electronic Failure; DTC P1AAE-1C: Charger Control Module "B" Power Supply (Plus) Circuit Voltage Out of Range; DTC P1AAF-1C: Charger Control Module "B" Power Supply (Minus) Circuit Voltage Out of Range; DTC P1AC9-1C: Charger Control Module "B" Power Supply (Offset) Circuit Voltage Out of Range; DTC P2D78-49: Charger Control Module "B" Processor Performance Internal Electronic Failure; DTC P2D78-87: Charger Control Module "B" Processor Performance Missing Message [08/2023 - ] |
| P2D78-87 |
Charger Control Module "B" Processor Performance Missing Message |
Comes on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P2D78 |
Refer to DTC P1A9F-49: Charger Control Module "B" A/D Processing Internal Electronic Failure; DTC P1AAE-1C: Charger Control Module "B" Power Supply (Plus) Circuit Voltage Out of Range; DTC P1AAF-1C: Charger Control Module "B" Power Supply (Minus) Circuit Voltage Out of Range; DTC P1AC9-1C: Charger Control Module "B" Power Supply (Offset) Circuit Voltage Out of Range; DTC P2D78-49: Charger Control Module "B" Processor Performance Internal Electronic Failure; DTC P2D78-87: Charger Control Module "B" Processor Performance Missing Message [08/2023 - ] |
| P3194-14 |
Internal Control Module Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Plug-in Control |
A |
SAE Code: P31CC |
Refer to DTC P0606-49: Plug-in Control Module Processor Internal Electronic Failure; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P0E5E-49: Hybrid/EV Battery Charger Control Module Internal Electronic Failure; DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message; DTC P1C1F-49: Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure; DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range; DTC P1CF3-1C: Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range; DTC P3194-14: Internal Control Module Circuit Short to Ground or Open [08/2023 - ] |
| P31D9-9F |
AC Inverter Status Signal Stuck Off |
Does not come on |
Master Warning: Does not come on |
Plug-in Control |
B |
SAE Code: P31D9 |
Refer to DTC P31D9-9F: AC Inverter Status Signal Stuck Off [08/2023 - ] |
| U0100-87 |
Lost Communication with ECM/PCM "A" Missing Message |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: U0100 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [08/2023 - ] |
| U0155-87 |
Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message |
Does not come on |
Master Warning: Does not come on |
Plug-in Control |
B |
SAE Code: U0155 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [08/2023 - ] |
| U0293-87 |
Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: U0293 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [08/2023 - ] |
| U1150-87 |
Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |
Comes on |
Master Warning: Comes on |
Plug-in Control |
B |
SAE Code: U1150 |
Refer to DTC U1150-87: Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message [08/2023 - ] |