Driver Side Power Window does not Operate with Power Window Master Switch [12/2021 - ]: Procedure

  1. READ VALUE USING GTS (D-DOOR MOTOR) 
    1. Read the Data List according to the display on the GTS.

      Body Electrical > D-Door Motor > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      D Door P/W Up SW Driver door power window manual up switch signal OFF or ON OFF: Driver door power window manual up switch not being operated
      ON: Driver door power window manual up switch being operated
      -
      D Door P/W Down SW Driver door power window manual down switch signal OFF or ON OFF: Driver door power window manual down switch not being operated
      ON: Driver door power window manual down switch being operated
      -

      Body Electrical > D-Door Motor > Data List 

      Tester Display
      D Door P/W Up SW
      D Door P/W Down SW

      OK

      On the GTS screen, ON or OFF is displayed accordingly.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to  REMOVAL [12/2021 - ] 

    Result: 

    NG 

    See step  2

  2. CHECK POWER WINDOW MASTER SWITCH ASSEMBLY WITH BEZEL 
    1. Disconnect the N5 front power window regulator motor assembly connector.
    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      N5-10 (UP) - N5-1 (GND)
      • Ignition switch ON
      • Power window master switch assembly with bezel (driver side switch) OFF → UP (manual operation)
      11 to 14 V → Below 1 V
      N5-7 (DOWN) - N5-1 (GND)
      • Ignition switch ON
      • Power window master switch assembly with bezel (driver side switch) OFF → DOWN (manual operation)
      11 to 14 V → Below 1 V

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to  REMOVAL [12/2021 - ] 

    Result: 

    NG 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (POWER WINDOW MASTER SWITCH ASSEMBLY WITH BEZEL - FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY) 
    1. Disconnect the N3 power window master switch assembly with bezel connector.
    2. Disconnect the N5 front power window regulator motor assembly connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      N3-20 (UP) - N5-10 (UP) Always Below 1 Ω
      N3-15 (DOWN) - N5-7 (DOWN) Always Below 1 Ω
      N3-20 (UP) or N5-10 (UP) - Body ground Always 10 kΩ or higher
      N3-15 (DOWN) or N5-7 (DOWN) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE POWER WINDOW MASTER SWITCH ASSEMBLY WITH BEZEL. Refer to  REMOVAL [12/2021 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR