Manifold Gauge Set Connection

WARNING: This page is about a different car, the 2003 Lincoln Aviator. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Special Tool(s)
G01636975Courtesy of FORD MOTOR CO.
  1. Turn both valves on the R-134a Manifold Gauge Set clockwise to close the low- and high-pressure hoses to the center manifold and center hose.
    Fig 2: Closing Both Valves On R-134a Manifold Gauge Set
    G01636976Courtesy of FORD MOTOR CO.
  2. Remove the A/C charging valve cap (19D702) from the low-pressure service gauge port valve.
    Fig 3: Removing A/C Charging Valve Cap (19D702) From Low-Pressure Service Gauge Port Valve
    G01636977Courtesy of FORD MOTOR CO.
  3. Remove the A/C charging valve cap from the high-pressure service gauge port valve.
    Fig 4: Removing A/C Charging Valve Cap From High-Pressure Service Gauge Port Valve
    G01636978Courtesy of FORD MOTOR CO.
  4. Connect the R-134a Manifold Gauge Set low-pressure hose and the R-134a low side quick disconnect to the low-pressure service gauge port valve.
    Fig 5: Connecting Low-Pressure Service Gauge To Port Valve
    G01636979Courtesy of FORD MOTOR CO.
  5. Connect the R-134a Manifold Gauge Set high-pressure hose and the R-134a high side quick disconnect to the high-pressure service gauge port valve.
    Fig 6: Connecting High-Pressure Service Gauge To Port Valve
    G01636980Courtesy of FORD MOTOR CO.