LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lincoln >> 2020 >> Navigator Base, RWD >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> DTC Index (Exterior Trim - Module Communications Network) >> Exterior Trim And Ornamentation DTCS
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Exterior Trim And Ornamentation DTCS

Diagnostics in this article assume a certain skill level and knowledge of Lincoln-specific diagnostic practices. REFER to: Diagnostic Methods .

DTC Description Action
C1002:77 Left Power Running Board Stow: Commanded Position Not Reachable Inspect for debris or corrosion at pivot points that may cause a slow moving PRB. CLEAN or repair as necessary. TEST the system for normal operation. If the concern returns, REPLACE the LH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1003:77 Right Power Running Board Stow: Commanded Position Not Reachable Inspect for debris or corrosion at pivot points that may cause a slow moving PRB. CLEAN or repair as necessary. TEST the system for normal operation. If the concern returns, REPLACE the RH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1004:77 Right Power Running Board Deploy: Commanded Position Not Reachable Inspect for debris or corrosion at pivot points that may cause a slow moving PRB. CLEAN or repair as necessary. TEST the system for normal operation. If the concern returns, REPLACE the RH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1005:77 Left Power Running Board Deploy: Commanded Position Not Reachable Inspect for debris or corrosion at pivot points that may cause a slow moving PRB. CLEAN or repair as necessary. TEST the system for normal operation. If the concern returns, REPLACE the LH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1006:11 Left Power Running Board Motor: Circuit Short To Ground GO to Pinpoint Test D
C1006:12 Left Power Running Board Motor: Circuit Short To Battery GO to Pinpoint Test D
C1006:13 Left Power Running Board Motor: Circuit Open GO to Pinpoint Test D
C1006:19 Left Power Running Board Motor: Circuit Current Above Threshold GO to Pinpoint Test D
C1007:11 Right Power Running Board Motor: Circuit Short To Ground GO to Pinpoint Test E
C1007:12 Right Power Running Board Motor: Circuit Short To Battery GO to Pinpoint Test E
C1007:13 Right Power Running Board Motor: Circuit Open GO to Pinpoint Test E
C1007:19 Right Power Running Board Motor: Circuit Current Above Threshold GO to Pinpoint Test E
C1008:3A Left Power Running Board Position/Motion Sensor: Signal Has Too Many Pulses Internal PRB motor damage. INSTALL a new LH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1008:93 Left Power Running Board Position/Motion Sensor: No Operation GO to Pinpoint Test F
C1009:3A Right Power Running Board Position/Motion Sensor: Signal Has Too Many Pulses Internal PRB motor damage. INSTALL a new RH PRB motor. REFER to: Power Running Board (PRB) Motor .
C1009:93 Right Power Running Board Position/Motion Sensor: No Operation GO to Pinpoint Test F
C1B14:11 Sensor Supply Voltage A: Circuit Short To Ground GO to Pinpoint Test F
C1B14:12 Sensor Supply Voltage A: Circuit Short To Battery GO to Pinpoint Test F
U0140:00 Lost Communication With BCM: No Sub Type Information GO to Pinpoint Test J
U0146:00 Lost Communication with Gateway "A": No Sub Type Information GO to Pinpoint Test G
U0422:00 Invalid Data Received From BCM: No Sub Type Information This DTC sets if the ignition signal status message is invalid for 5 seconds. Using a diagnostic scan tool, RETRIEVE and DIAGNOSE all BCM DTC. REFER to: Body Control Module (BCM) .
If no Diagnostic Trouble Codes (DTCs) are present in the BCM, the condition may be caused by an intermittent concern. SET the ignition to OFF. DISCONNECT and INSPECT all BCM electrical connectors and related in-line connectors for corrosion, bent pins, pushed-out pins and spread terminals. REPAIR as necessary.
U1000:00 Solid State Driver Protection Active: Driver Disabled: No Sub Type Information GO to Pinpoint Test K
U3000:09 Control Module: Component Failure CLEAR the Diagnostic Trouble Codes (DTCs). CARRY OUT the RBM self-test. RETRIEVE and RECORD all Diagnostic Trouble Codes (DTCs).
If the DTC returns, INSTALL a new RBM. REFER to: Running Board Control Module (RBM) .
U3000:41 Control Module: General Checksum Failure CLEAR the Diagnostic Trouble Codes (DTCs). CARRY OUT the RBM self-test. RETRIEVE and RECORD all Diagnostic Trouble Codes (DTCs).
If the DTC returns, INSTALL a new RBM. REFER to: Running Board Control Module (RBM) .
U3000:49 Control Module: Internal Electronic Failure CLEAR the Diagnostic Trouble Codes (DTCs). CARRY OUT the RBM self-test. RETRIEVE and RECORD all Diagnostic Trouble Codes (DTCs).
If the DTC returns, INSTALL a new RBM. REFER to: Running Board Control Module (RBM) .
U3000:4B Control Module: Over Temperature CLEAR the Diagnostic Trouble Codes (DTCs). CARRY OUT the RBM self-test. RETRIEVE and RECORD all Diagnostic Trouble Codes (DTCs).
If the DTC returns, INSTALL a new RBM. REFER to: Running Board Control Module (RBM) .
U3003:16 Control Module: Circuit Voltage Below Threshold GO to Pinpoint Test H
U3003:17 Control Module: Circuit Voltage Above Threshold GO to Pinpoint Test I