July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

KOEO Wiggle Test Procedure

1)  Connect test equipment. Turn ignition on and activate self-test with jumper lead or diagnostic tester. Wait 10 seconds, deactivate and then reactivate self-test. Wiggle test mode is now activated. Tap, move and wiggle suspect sensor and/or harness area.

2)  If a fault is detected, a service code may be stored in memory and indicated at diagnostic tester or scan tester. If voltmeter is used, needle will sweep. If using CHECK ENGINE light, light will come on. Record code, and perform CIRCUIT TEST listed in CONTINUOUS MEMORY CODE REFERENCE table.