LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 1998 >> Millenia V6-2.5L DOHC >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Oxygen Sensor >> Testing and Inspection >> Testing With SST
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Testing With SST




1. Connect the SST to the data link connector-2.
2. Select the PID/DATA MONITOR AND RECORD function of NGS.




3. Select "FHO2S R", "FHO2S L", "MHO2S" and "RHO2S" on the NGS display. NGS measures and shows the voltage.




Specification

4. If not as specified, inspect following.
- Intake-air system
- Fuel system
- On-board diagnosis system
If these systems are okay, replace the heated oxygen sensor.

Tightening torque
30 - 49 N.m {3.0 - 5.0 kgf.m, 22 - 36 ft.lbf}