LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2002 >> B4000 Base, Standard >> Repair and Diagnosis (Single Page) >> General Information >> Map - Exhaust Systems >> Exhaust Systems >> Catalytic Converters
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Catalytic Converters

Condition Code Procedure
Air injection tube broken A Require repair or replacement of injection tube or replacement of catalytic converter
Air injection tube burnt A Require repair or replacement of injection tube or replacement of catalytic converter
Air injection tube leaking A Require repair or replacement of injection tube or replacement of catalytic converter
Air injection tube loose A Require repair or replacement of injection tube or replacement of catalytic converter
Air injection tube restricted A Require repair or replacement of injection tube or replacement of catalytic converter
Air injection tube threads damaged A Require repair or replacement of injection tube or replacement of catalytic converter
Air injection tube threads stripped (threads missing) A Require repair or replacement of injection tube or replacement of catalytic converter
Body Cracked B Require repair or replacement
Converter empty A Require repair or replacement
Converter fill plug missing C Require repair or replacement
Converter missing C Require repair or replacement
Exhaust gases leaking A Require repair or replacement
Flanges leaking A Require repair or replacement of flanges
Inlet pipes cracked B Require repair or replacement
Internal rattle (except pellet-type) 2 Further Inspection required
NOTE: If the converter is breaking up, suggest converter replacement. If an object has fallen into the converter, remove object
Mounting brackets that are part of converter broken A Require repair or replacement
Obvious overheating Require testing of converter
NOTE: Overheating is caused by something other than the converter. Further diagnosis is required to determine the cause of the overheating.
Outlet pipes cracked B Require repair or replacement
Pieces of catalyst material found downstream 1 Suggest replacement
Plugged A Require replacement
NOTE: Determine cause and correct to ensure that new converter will not become plugged.
Testing has determined that existing converter has been lead-poisoned, contaminated or failed testing A Require repair or replacement