Fan Control Module Inspection
- Remove the two bolts from the fan control module with the connectors still connected.
- Start and warm up the engine.
- Monitor the engine coolant temperature with the WDS
or equivalent.
- Measure the voltage at the terminal B of cooling fan control module connector (2 terminals) from the harness side as shown in the table.
Courtesy of MAZDA MOTORS CORP.
Courtesy of MAZDA MOTORS CORP.
- If not as specified, replace the fan control module.