Output Test Mode Procedure
- Perform the "New Generation Star (NGS) Tester Hook-Up Procedure". See ON-BOARD DIAGNOSTIC TEST - NEW GENERATION STAR (NGS) TESTER HOOK-UP PROCEDURE .
- Perform step 1 through step 7 from the "Retrieving DTCs Procedure".
- Turn key on.
- Move the cursor to ACTIVE COMMAND MODES . Press the trigger key to enter this selection.
- Move the cursor to OUTPUT TEST MODE . Press the trigger key to enter this selection.
- Press MODE repeatedly to change the mode from ALL ON to LOW FAN, HIGH FAN, and ALL OFF . Return the mode to ALL ON .
- Press START to run the fuel pump. Press STOP to turn off the fuel pump.
- To open and close certain actuators in the emission system, press PIDS .
- Press CLEAR
to clear previous selected PIDs.NOTE:
- To select desired PIDs, place the shaded bar over the item(s) and press trigger. A star symbol appears next to the item when it's selected. Press START
. The selected PID(s) and values appear.
You can select 30 PIDs at a time.
- To select desired PIDs, place the shaded bar over the item(s) and press trigger. A star symbol appears next to the item when it's selected. Press START
. The selected PID(s) and values appear.
- Press START to turn on the fuel pump. Observe the values change from OFF to ON or from 0% to 100%. Press STOP to turn off the fuel pump.