Possible Causes
- ISO 9141 communication network circuit (LB/W) open
- SJB J-2280d
- SJB
CAUTION:
- Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
SMART JUNCTION BOX (SJB) DOES NOT RESPOND TO DIAGNOSTIC TOOL PINPOINT TEST REFERENCE
| PIN POINT TEST 1 | SMART JUNCTION BOX (SJB) DOES NOT RESPOND TO THE DIAGNOSTIC TOOL | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK THE SJB CONNECTORS FOR DAMAGE Key OFF. Disconnect: SJB J-2280d. Inspect the SJB J-2280d for damage. Is the SJB J-2280d OK? |
Yes | Go to next step. |
| No | Repair the SJB J-2280d. Carry out the WDS or equivalent tester data link test. | ||
| 2 | CHECK THE ISO 9141 CIRCUIT BETWEEN THE DLC AND THE SJB FOR AN OPEN
|
Yes | Go to See step 3. |
| No | Repair circuit (LB/W) for an open. Connect SJB J-2280d. Carry out the WDS or equivalent tester data link test. | ||
| 3 | CHECK FOR CORRECT SJB OPERATION
|
Yes | Install a new SJB. See SMART JUNCTION BOX (SJB) . Carry out the WDS or equivalent tester data link test. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. Clear the diagnostic trouble codes (DTCs). Repeat the self-test. Carry out the WDS or equivalent tester data link test. | ||