Hardware Limited Operation Strategy (HLOS)
This system of special circuitry provides minimal engine operation should the PCM [mainly the central processing unit (CPU) or FEEPROM] stop functioning correctly. All modes of self-test are not functional at this time. Electronic hardware is in control of the system while in HLOS.
HLOS Allowable Output Functions:
- spark output controlled directly by the CKP signal
- fixed fuel pulse width synchronized with the CKP signal
- fuel pump relay energized
- idle cruise control output signal functional
HLOS Disabled Outputs To Default State:
- EGR solenoids
- no torque converter clutch lock-up
PCM Location:
- Behind instrument panel (cowl), center to both driver and passenger sides