Diagnostic procedure
DTC P0125 DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA AND DIAGNOSTIC MONITORING TEST RESULTS HAVE BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record FREEZE FRAME DATA and DIAGNOSTIC MONITORING TEST RESULTS on the repair order, then go to the next step. | ||
| 2 | VERIFY RELATED SERVICE INFORMATION AVAILABILITY
|
Yes | Perform the repair or diagnosis according to available Service, Information.
|
| No | Go to the next step. | ||
| 3 | VERIFY CURRENT INPUT SIGNAL STATUS: IS CONCERN INTERMITTENT OR CONSTANT
|
Yes | Intermittent concern exists. Go to the INTERMITTENT CONCERNS TROUBLESHOOTING procedure. (See INTERMITTENT CONCERN TROUBLESHOOTING ). |
| No | Go to the next step. | ||
| 4 | INSPECT ECT SENSOR CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace the terminal, then go to Step 7. |
| No | Go to the next step. | ||
| 5 | INSPECT ECT SENSOR
|
Yes | Go to the next step. |
| No | Replace the ECT sensor, then go to Step 7. | ||
| 6 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace the terminal, then go to the next step. |
| No | Go to the next step. | ||
| 7 | VERIFY TROUBLESHOOTING OF DTC P0125 COMPLETED
|
Yes | Replace the PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION ). |
| No | Go to the next step. | ||
| 8 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC troubleshooting. (See DTC TABLE ). |
| No | Troubleshooting completed. | ||