DTC P0344: Notes
DTC P0344 (MZI-3.5) DETECTION CONDITION AND POSSIBLE CAUSES
| DTC P0344 |
CMP sensor (RH) circuit intermittent |
| DETECTION CONDITION |
- The test fails when the PCM detects an intermittent signal from the CMP sensor.
|
| POSSIBLE CAUSE |
- Connector or terminal malfunction
- CMP sensor (RH) malfunction
- Sensor shielding malfunction
- Short to ground circuit between CMP sensor (RH) terminal A and PCM terminal 2X
- Short to power supply between CMP sensor (RH) terminal A and PCM terminal 2X
- Open circuit between CMP sensor (RH) terminal A and PCM terminal 2X
- Open circuit between CMP sensor (RH) terminal B and PCM terminal 2C
|
Courtesy of MAZDA MOTORS CORP.
|