Stopper Assembly Note
- Assemble the stopper.
- Inspect airtightness.
- Connect the SST to the power cylinder section of the gear housing
- Apply 53.3 kPa {400 mmHg, 15.8 inHg}
vacuum with a vacuum pump and verify that it is held for 30 s.
- If the vacuum is not held, replace the oil seal.