Diagnostic procedure
DTC P2017 [L3] DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA (MODE 12) HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record the FREEZE FRAME DATA (Mode 12) on the repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | INSPECT VARIABLE TUMBLE SHUTTER VALVE SWITCH CONNECTOR CONDITION
|
Yes | Repair or replace the terminal and/or connector, then go to Step 9. |
| No | Go to the next step. | ||
| 4 | INSPECT PCM CONNECTOR CONDITION
|
Yes | Repair or replace the terminal and/or connector, then go to Step 9. |
| No | Go to the next step. | ||
| 5 | INSPECT VARIABLE TUMBLE SHUTTER VALVE SWITCH POWER SUPPLY AND SIGNAL CIRCUITS FOR SHORT TO EACH OTHER
|
Yes | Repair or replace the malfunctioning wiring harness, then go to Step 9. |
| No | Go to the next step. | ||
| 6 | INSPECT VARIABLE TUMBLE SHUTTER VALVE SWITCH SIGNAL CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Repair or replace the wiring harness for a possible short to power supply, then go to Step 9. |
| No | Go to the next step. | ||
| 7 | INSPECT VARIABLE TUMBLE SHUTTER VALVE SWITCH CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit, then go to Step 9. | ||
| 8 | INSPECT VARIABLE TUMBLE SHUTTER VALVE SWITCH
|
Yes | Replace the variable tumble shutter valve switch, then go to the next step. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 9 | VERIFY DTC TROUBLESHOOTING COMPLETED
|
Yes | Replace the PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 10 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
| No | DTC troubleshooting completed. | ||