| DETECTION CONDITION |
- The actual valve timing is over-retarded by 16 °
from the target valve timing for specified period when the OCV system control is within the feedback range.
Diagnostic support note
- This is a continuous monitor (CCM).
- The MIL illuminates if the PCM detects the above malfunction condition in two consecutive drive cycles or in one drive cycle while the DTC for the same malfunction has been stored in the PCM.
- PENDING CODE is available if the PCM detects the above malfunction condition during first drive cycle.
- FREEZE FRAME DATA (Mode 2)/Snapshot data is available.
- The DTC is stored in the PCM memory.
|