| Possible Causes |
- Power window main switch malfunction
- Short to ground in wiring harness between the following terminals:
- Power window main switch terminal 1D and power window subswitch (RF) terminal E
- Power window main switch terminal 1B and power window subswitch (RF) terminal B
- Power window main switch terminal 1I and power window subswitch (LR) terminal E
- Power window main switch terminal 1G and power window subswitch (LR) terminal B
- Power window main switch terminal 1C and power window subswitch (RR) terminal E
- Power window main switch terminal 1A and power window subswitch (RR) terminal B
- Open circuit in wiring harness between the following terminals:
- Power window main switch terminal 1D and power window subswitch (RF) terminal E
- Power window main switch terminal 1B and power window subswitch (RF) terminal B
- Power window main switch terminal 1I and power window subswitch (LR) terminal E
- Power window main switch terminal 1G and power window subswitch (LR) terminal B
- Power window main switch terminal 1C and power window subswitch (RR) terminal E
- Power window main switch terminal 1A and power window subswitch (RR) terminal B
- Connector poor contact or terminal damage
|