Up Switch: Notes
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)] .)
- Remove the screw.
- Disconnect the up switch connector.
- Remove the column cover. (See COLUMN COVER REMOVAL/INSTALLATION .)
- Verify that the continuity between up switch component terminals A and B.
- If there is any malfunction, replace the up switch.