Sensor O2cconnectors swapped, ME-SFI fault code description - AD07.61-P-4000-72L
| At least two O2 sensor connectors upstream TWC have been swapped | ||
|---|---|---|
| 1 | Fault code ( |
P2090 (-) |
| 2 | Fault storage | After expiry of test duration and fault |
| Activation of the engine diagnosis indicator lamp (EURO3/4) or CHECK ENGINE (MIL) malfunction indicator lamp |
No activation | |
| 3 | Checking frequency | Continuous |
| 4 | Checked signal or status | Closed-loop mixture control |
| 5 | Fault setting conditions | The Lamda controls for the swapped O2 sensors move in an opposite direction up to the enrichment or lean stop. If they remain above the limit values for longer than 15 s, a fault is detected. |
| 6 | Check prerequisites | Enable the affected Lambda controls. |
| 6 | For the swapped O2 sensor connectors, self-adaptation of the mixture formation and actuation of the purge control valve are blocked. |