LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercury >> 1982 >> LN7 Automatic Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Auto. A/C Systems >> Adjustments >> Sensor Calibration >> All Models
April 5, 2026: LEMON Manuals is launched! Read the announcement.

All Models

Remove instrument panel pad and visually determine which direction to rotate sensor calibration locking pin. See Fig 1. While moving temperature control lever, rotate calibration locking pin into notch of control arm. Control lever should now be at "75". if not, loosen cable retaining screw and move lever to "75". Be sure calibration pin remains in notch. Tighten cable retaining screw and check operation.

Fig 1: Showing Adjustment Points for ATC Temperature Calibration
G09361745Courtesy of FORD MOTOR CO.