Fail-Safe Function
4F20E transaxle is equipped with a fail-safe control system. Fail-safe function is controlled by TCM and is designed to allow transaxle operation when damage to transaxle is detected. Fail-safe function will be activated if damage to any of the following components is detected.
- Coasting Clutch Solenoid
- Line Pressure Solenoid
- Transmission Range (TR) Sensor
- Shift Solenoids "A" or "B"
- Throttle Position (TP) Sensor
- Torque Converter Clutch (TCC) Solenoid
- Vehicle Speed Sensor (VSS)
- Output Shaft Speed (OSS) Sensor
Fail-safe function can also be activated by excessive wheel spin.