LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercury >> 2004 >> Monterey >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> A/C Compressor >> HVAC Control System >> Diagnosis And Testing >> Climate Control System >> Connector Circuit Reference >> Solar Radiation Sensor C286
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Solar Radiation Sensor C286

Fig 1: Identifying Solar Radiation Sensor C286
G03245312Courtesy of FORD MOTOR CO.
SOLAR RADIATION SENSOR C286 CIRCUIT REFERENCE

Pin Number (s) Circuit Designation/Description Normal Condition/Measurement
1 CKT 468 (BN) solar radiation sensor input (LH) Approximately 5 volts with the EATC ON.
5 CKT 1203 (BK/LB) ground Resistance of 0 ohms to chassis ground.
6 CKT 476 (PK/YE) solar radiation sensor input (RH) Approximately 5 volts with the EATC ON.