Component Testing: THERMOSENSOR

Connect vacuum pump to thermosensor nipple and apply vacuum. At 86°F (30°C) or less, vacuum should hold. At 113°F (45°C) or more, vacuum should leak.

Fig 1: Thermostatic Air Cleaner System
G65450Courtesy of CHRYSLER MOTORS.