Automatic Stop Operation Check
- To check automatic operation, connect battery positive voltage to one terminal and battery negative voltage to another terminal as shown in AUTOMATIC STOP OPERATION TERMINAL NUMBER table. While motor is operating, disconnect battery positive terminal to stop motor.
- Using a jumper wire, connect one terminal to another. Connect battery positive voltage to another terminal and battery negative voltage to wiper motor bracket. Ensure motor starts to run, then stops. See JUMPER WIRE/BATTERY POSITIVE TERMINAL NUMBERS - REAR WIPER table for terminal numbers and model application.
AUTOMATIC STOP OPERATION TERMINAL NUMBERS
| Model | Voltage (-): Pin No. | Voltage (+): Pin No. |
|---|---|---|
| Cordia | 1 | 3 |
| Mirage | 4 | 1 |
| Montero | 3 | 1 |
| Precis | A | B |
| Starion | 4 | 3 |
| Tredia | 1 | 3 |
| Van/Wagon | Ground | 3 |
JUMPER WIRE/BATTERY POSITIVE TERMINAL NUMBERS - REAR WIPER
| Model | Jumper Wire Pin Nos. | Voltage (+) Pin No. |
|---|---|---|
| Cordia | 1-2 | 3 |
| Mirage | 3-4 | 1 |
| Montero | 2-3 | 1 |
| Starion | 1-4 | 3 |
| Tredia | 1-2 | 3 |
| Van/Wagon | 2-3 | 1 |