Automatic Stop Check
- Connect 12 volts one terminal and ground other terminal. Disconnect jumper wires during operation to stop motor. See AUTOMATIC STOP TERMINAL NUMBERS for terminals and model application.
- Using a jumper wire, connect 2 terminals together. Connect 12 volts to other terminal and ground wiper motor bracket. Ensure motor runs, then stops. See JUMPER WIRE/BATTERY POSITIVE TERMINAL NUMBERS - FRONT . SeeFigure .
AUTOMATIC STOP TERMINAL NUMBERS
| Model | Voltage (-) Terminal No. | Voltage (+) Terminal No. |
|---|---|---|
| Cordia/Tredia | 1 | 4 |
| Galant | 6 | 1 |
| Mirage | 1 | 3 |
| Montero | 3 | 1 |
| Pickup | 1 | 3 |
| Starion | 1 | 4 |
| Van/Wagon | Ground | 1 |
JUMPER WIRE/BATTERY POSITIVE TERMINAL NUMBERS - FRONT
| Model | Jumper Wire Terminals No. | Voltage (+) Terminal No. |
|---|---|---|
| Cordia/Tredia | 1-3 | 4 |
| Galant | 5-6 | 1 |
| Mirage | 1-4 | 3 |
| Montero | 3-2 | 1 |
| Pickup | 1-4 | 3 |
| Starion | 1-3 | 4 |
| Van/Wagon | 1-4 | 3 |