Mixture Control Valve (Manual Transmission Only)
- Remove air cleaner. Start engine and bring to operating temperature. Observe mixture control valve.
- Open and close throttle valve quickly. Mixture control valve should pop out once then close quickly. Air suction should be heard. Return engine to idle. Valve should remain closed and no air suction heard.