Fuel Pressure Regulator Control Solenoid Valve (Turbo)
- Label and remove vacuum hoses from solenoid valve, mounted to left end of firewall. Disconnect wiring harness. Connect a vacuum pump to nipple where Black vacuum hose was connected; leave pump connected throughout testing procedure.
- Apply vacuum and ensure vacuum leaks. Plug nipple where Blue-striped hose was connected. Apply vacuum and ensure vacuum holds. Remove plug from Blue-striped hose nipple. Apply battery voltage across valve terminals. Apply vacuum and ensure vacuum holds.
- Using an ohmmeter, check resistance across terminals of solenoid. Resistance should be 36-46 ohms at 68°F (20°C). If resistance is as specified, replace valve.