TP Sensor Adjustment: Montero
- Disconnect TP sensor connector. Using jumper wires, connect an external ohmmeter between TP sensor terminals No. 1 and 2. See Figure. Insert .025" (.65 mm) feeler gauge between fixed speed adjusting screw and throttle lever.
- Loosen TP sensor mounting screws and rotate TP sensor fully clockwise. Ensure there is continuity between terminals No. 1 and 2. Rotate TP sensor counterclockwise until there is no continuity, and tighten screws. Install Test Harness (MB991348) between TP sensor and harness connector.
- Turn ignition on. Using external voltmeter, measure TP sensor output voltage between terminals No. 1 and 3. If voltage is not .4-1.0 volt, check harness and sensor. See DTC P0120 in appropriate TESTS W/CODES article.