Main Switch
Remove power window main switch from trim panel. Apply battery positive voltage to switch terminals No. 1, 9 and 23. Apply battery ground to switch terminal No. 24. See Figure . Continuity should be present at specified terminals. See Figure . If continuity is not as specified, replace power window main switch.