DTC Set Criteria
- Engine speed is 1600 RPM or more. Intake manifold pressure is 3.0-13.5 psi (27-93 kPa). Volumetric efficiency is 20-80 percent (1.8L). Purge solenoid is driven at 100 percent duty cycle when intake air temperature is 41-113°F (5-45°C). Code will set if Fuel Tank Differential Pressure (FTDP) sensor output voltage is 4 volts or more for 10 seconds.
- Engine speed is 1600 RPM or more. Intake manifold pressure is 3.0-13.5 psi (27-93 kPa). Volumetric efficiency is 20-80 percent (1.8L). Purge solenoid is not driven when intake air temperature is more than 41-113°F (5-45°C). Code will set if FTDP sensor output voltage is less than one volt for 10 seconds.