No Communication With All Systems
A battery positive voltage is applied on the data link connector power terminal (terminal 16). The ground terminals (terminal 4, 5) are grounded to the vehicle body.
NOTE:
The cause of the fault is probably a defect in power supply system (including ground) for the on-board diagnostic test mode line. The most likely causes for this case are malfunction of the data link connector or a damaged harness wire.
- Measure the voltage between terminal 16 and ground. See Figure. If the voltage shows normal (battery positive voltage), go to step 3, otherwise go to next step.
- Check harness connectors C-108, C-113 and C-89 at intermediate connector for damage, and repair or replace as required. If intermediate connectors are in good condition, repair harness wire between fusible link (2) and data link connector C-29, terminal 16 because of open circuit. Then confirm that the malfunction symptom is eliminated.
- Check for continuity between terminals 4, 5 and ground (the resistance should be less than 2 ohms). If the continuity is normal, replace the scan tool and confirm that the malfunction symptom has been eliminated. If the continuity is not normal, repair harness wire between data link connector C-29, terminal 4, 5 and ground because of open circuit or harness damage. Confirm that the malfunction has been eliminated.