Key Interlock Mechanism Check
- Carry out the following inspection.
- When any of the above checks are not normal, adjust the key interlock cable in following procedure.
- Remove the floor console.
- Shift the selector lever to "P" position.
- Turn the ignition key to "LOCK" (OFF) position.
- Loosen the locking nut of the key interlock cable.
Tightening torque: 11 N.m (97 in-lb)
- Push the cable joint on the lock cam gently toward the arrow until the cable stops. Tighten the locking nut.
- Install the floor console.
- After adjusting, check the operation once more. If the operation is still incorrect, replace the key interlock cable. See A/T KEY INTERLOCK AND SHIFT LOCK MECHANISMS .