LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2003 >> Lancer LS >> Repair and Diagnosis (Single Page) >> Body & Frame >> Door Locks >> Keyless Entry System - Except Evolution >> On-Vehicle Service >> Enabling/Disabling The Hazard ANSWERBACK Function >> When The Transmitter Is Used After Connecting Scan Tool MB991502 To The Data Link Connector Or Grounding Data Link Connector Terminal No. 1
April 5, 2026: LEMON Manuals is launched! Read the announcement.

When The Transmitter Is Used After Connecting Scan Tool MB991502 To The Data Link Connector Or Grounding Data Link Connector Terminal No. 1

Fig 1: Connecting Scan Tool MB991502
G00369300Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  1. Enter the hazard answerback customize mode by observing one of the following steps. If the ETACS-ECU enters the customize mode, its tone alarm will sound once.
    • Turn the ignition switch to LOCK (OFF) position.
    • Turn off the hazard warning light switch.
    • Connect Scan Tool MB991502 to the data link connector terminal No. 1.
    • Close the driver's side door.
    • Leave the windshield washer switch on for at least 10 seconds. Then the ETACS-ECU tone alarm will sound once.
  2. If the transmitter LOCK switch is pushed consecutively twice (within 2 seconds), the ETACS-ECU tone alarm will sound, indicating that the hazard answerback function can be enabled or disabled when the doors are locked.
    • Enable the hazard answerback function when the doors are locked: The ETACS-ECU tone alarm will sound once.
    • Disable the hazard answerback function when the doors are locked: The ETACS-ECU tone alarm will sound twice.
  3. If the transmitter UNLOCK switch is pushed consecutively twice (within 2 seconds), the ETACS-ECU tone alarm will sound, indicating that the hazard answerback function can be enabled or disabled when the doors are unlocked.
    • Enable the hazard answerback function when the doors are locked: The ETACS-ECU tone alarm will sound once.
    • Disable the hazard answerback function when the doors are locked: The ETACS-ECU tone alarm will sound twice.
  4. Exit the hazard answerback customize mode by observing one of the following steps:
    • Disconnect Scan Tool MB991502 from the data link connector, or disconnect data link connector terminal No. 1 from the ground.
    • Turn the ignition switch to position other than LOCK (OFF), or remove the ignition key.
    • Open the driver's side door.
    • NOTE: If any operation is not done for at least 3 minutes after the ETACS-ECU has entered the customize mode, the hazard answerback customize mode will be canceled automatically.
    • Any other warning tone alarm output occurs.