INSPECTION PROCEDURE 2: Accelerator Pedal Operation Not Smooth (Over Acceleration): Diagnosis
Required Special Tool:
- MB991958: Scan Tool (MUT-III sub assembly)
- MB991824: V.C.I.
- MB991827: USB Cable
- MB991910: Main Harness A
- STEP 1. Check if the accelerator pedal and the accelerator pedal are installed correctly.
Q: Are the accelerator pedal and the accelerator pedal installed correctly?
- YES: Go to Step 2.
- NO: Replace and reinstall the accelerator pedal. Refer to ACCELERATOR CABLE AND PEDAL . Go to Step 3.
- STEP 2. Using scan tool MB991958, read the diagnostic trouble code (DTC). CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
- Ensure that the ignition switch is at the "LOCK" (OFF) position.
- Start up the personal computer.
- Connect special tool MB991827 to special tool MB991824 and the personal computer.
- Connect special tool MB991910 to special tool MB991824.
- Connect special tool MB991910 to the data link connector.
- Turn the power switch of special tool MB991824 to the "ON" position.NOTE: When special tool MB991824 is energized, special tool MB991824 indicator light will be illuminated in a green color.
- Start the MUT-III system on the personal computer.
- Turn the ignition switch to the "ON" position.
- Check for MFI system diagnostic trouble code. Refer to MFI DIAGNOSISMULTIPORT FUEL INJECTION (MFI) DIAGNOSIS - 2.4L or MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS - 3.8L .
- Turn the ignition switch to the "LOCK" (OFF) position, and then remove scan tool MB991958 in the reverse order of installation.
Q: Is any DTC set?
- YES: Refer to DIAGNOSTIC TROUBLE CODE CHARTMULTIPORT FUEL INJECTION (MFI) DIAGNOSIS - 2.4L or MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS - 3.8L .
- NO: Go to Step 3.
- STEP 3. Retest the system.
Q: Does the accelerator pedal work normally?
- YES: The procedure is complete.
- NO: Return to Step 1.