Inspection Procedure 5: Combination Meter Does Not Work.: Diagnosis
WARNING: This page is about a different variant/trim than selected.
Required Special Tool:
- MB991223: Harness Set
- STEP 1. Measure at combination meter connector C-02 in order to check the battery circuit of power supply system to the combination meter.
- Disconnect combination meter connector C-02, and measure at the wiring harness side.
- Measure the voltage between terminal 7 and ground.
- The measured value should be approximately 12 volts (battery positive voltage).
Q: Does the measured voltage correspond with this range?
- YES: Go to Step 4.
- NO: Go to Step 2.
- STEP 2. Check combination meter connector C-02 for damage.
Q: Is combination meter connector C-02 in good condition?
- YES: Go to Step 3.
- NO: Repair or replace the connector. Refer to HARNESS CONNECTOR INSPECTION . Check to see that all meters operate.
- STEP 3. Check the wiring harness between combination meter connector C-02 (terminal 7) and battery.
NOTE: Also check intermediate connector C-124. If intermediate connector (1) C-09. If intermediate connectors C-124 or joint connector (1) C-09 is damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .
Q: Are the wiring harness between combination meter connector C-02 (terminal 7) and battery in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.
- STEP 4. Measure at combination meter connector C-02 in order to check the battery circuit of power supply system to the combination meter.
- Disconnect combination meter connector C-02, and measure at the wiring harness side.
- Turn the ignition switch to "ON" position.
- Measure the voltage between terminal 9 and ground.
- The measured value should be approximately 12 volts (battery positive voltage).
Q: Does the measured voltage correspond with this range?
- YES: Go to Step 7.
- NO: Go to Step 5.
- STEP 5. Check combination meter connector C-02 for damage.
Q: Is combination meter connector C-02 in good condition?
- YES: Go to Step 6.
- NO: Repair or replace the connector. Refer to HARNESS CONNECTOR INSPECTION . Check to see that all meters operate.
- STEP 6. Check the wiring harness between combination meter connector C-02 (terminal 2) and ignition switch (IG1).
NOTE: Also check junction block connectors C212, C-215 and joint connector (5) C-03. If junction block connectors C-212, C-215 or joint connector (5) C-03 are damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .
Q: Are the wiring harness between combination meter connector C-02 (terminal 9) and ignition switch (IG1) in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.
- STEP 7. Measure at combination meter connector C-02 in order to check the ground circuit to the combination meter.
- Disconnect combination meter connector C-02, and measure at the wiring harness side.
- Measure the resistance between terminal 1 and ground.
- The measured value should be 2 ohms or less.
- Measure the resistance between terminal 2 and ground.
- The measured value should be 2 ohms or less.
Q: Does the measured voltage correspond with this range?
- YES: Repair the combination meter. Check to see that all meters operate.
- NO: Go to Step 8.
- STEP 8. Check combination meter connector C-02 for damage.
Q: Is combination meter connector C-02 in good condition?
- YES: Go to Step 9.
- NO: Repair or replace the connector. Refer to HARNESS CONNECTOR INSPECTION . Check to see that all meters operate.
- STEP 9. Check the wiring harness between combination meter connector C-02 (terminal 1 and 2) and ground.
Q: Are the wiring harness between combination meter connector C-02 (terminal 1 and 2) and ground in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.