How To Connect The Scan Tool (Mut-III)
Required Special Tools:
- MB991958: Scan Tool (MUT-III Sub Assembly)
- MB991824: Vehicle Communication Interface (V.C.I.)
- MB991827: MUT-III USB Cable
- MB991910: MUT-III Main Harness A
CAUTION:
To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
- Ensure that the ignition switch is at the "LOCK" (OFF) position.
- Start up the personal computer.
- Connect special tool MB991827 to special tool MB991824 and the personal computer.
- Connect special tool MB991910 to the V.C.I.
- Connect special tool to the data link connector.
- Turn the V.C.I. power switch to the "ON" position.NOTE: When the V.C.I. is energized, the V.C.I. indicator light will be illuminated in a green color.
- Start the MUT-III system on the personal computer.
NOTE:
Disconnect the scan tool in the reverse order of the connecting sequence, making sure that the ignition switch is at the "LOCK" (OFF) position.