>> A << Pre-Installation Inspection
WARNING:
Dispose of air bag modules only according to the specified procedure (Refer to AIR BAG MODULE AND SEAT BELT PRE-TENSIONER DISPOSAL PROCEDURES
.)
- When installing the new air bag modules and clock spring, refer to "INSPECTION "
- Connect the negative (-) battery cable.CAUTION: To prevent damage to scan tool MB991958, always turn the ignition, switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
- Connect scan tool MB991958 to the data link connector.
- Turn the ignition switch to the "ON" position.
- Check DTCs using scan tool MB991958 to ensure entire SRS operates properly.
Confirm that the DTCs other than 21 and 24 are not set.
DANGER
Wait at least 60 seconds after disconnecting the battery cable before doing any further work (Refer to SERVICE PRECAUTIONS .)
WARNING: Battery posts, terminals and related accessories contain lead and lead compounds. WASH HANDS AFTER HANDLING. - Turn the ignition switch to the "LOCK" (OFF) position. Disconnect the negative (-) battery cable and tape the terminal to prevent accidental connection and air bags deployment.