INSPECTION PROCEDURE 5: Combination Meter does not Work.: Diagnosis
Required Special Tools:
- MB991223: Harness Set
- STEP 1. Measure at combination meter connector D-03 in order to check the battery circuit of power supply system to the combination meter.
- Disconnect combination meter connector D-03, and measure at the wiring harness side.
- Measure the voltage between terminal 67 and ground.
- The voltage should equal approximately 12 volts (battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery positive voltage)?
- YES: Go to Step 4.
- NO: Go to Step 2.
- STEP 2. Check combination meter connector D-03 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
Q: Is combination meter connector D-03 in good condition?
- YES: Go to Step 3.
- NO: Repair or replace the damaged component(s). Refer to HARNESS CONNECTOR INSPECTION . Check to see that all meters operate.
- STEP 3. Check the wiring harness between combination meter connector D-03 (terminal 67) and the battery.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
NOTE: Also check intermediate connector D-28, junction block connector D-217 and D-221. If intermediate connector D-28, junction block connector D-217 and D-221 is damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .Q: Is the wiring harness between combination meter connector D-03 (terminal 67) and the battery in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.
- STEP 4. Measure at combination meter connector D-03 in order to check the ignition switch (IG1) circuit of power supply system to the combination meter.
- Disconnect combination meter connector D-03, and measure at the wiring harness side.
- Turn the ignition switch to "ON" position.
- Measure the voltage between terminal 62 and ground.
- The voltage should equal approximately 12 volts (battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery positive voltage)?
- YES: Go to Step 7.
- NO: Go to Step 5.
- STEP 5. Check combination meter connector D-03 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
Q: Is combination meter connector D-03 in good condition?
- YES: Go to Step 6.
- NO: Repair or replace the damaged component(s). Refer to HARNESS CONNECTOR INSPECTION . Check to see that all meters operate.
- STEP 6. Check the wiring harness between combination meter connector D-03 (terminal 62) and ignition switch (IG1).
NOTE: Also check junction block connectors D-208 and D-210. If junction block connector D-208 or D-210 is damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .
Q: Is the wiring harness between combination meter connector D-03 (terminal 62) and ignition switch (IG1) in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.
- STEP 7. Measure at combination meter connector D-32 in order to check the ground circuit to the combination meter.
- Disconnect combination meter connector D-32, and measure at the wiring harness side.
- Measure the resistance between terminal 25 and ground.
- The resistance should equal 2 ohms or less.
- Measure the resistance between terminal 11 and ground.
- The resistance should equal 2 ohms or less.
Q: Is the measured voltage approximately 12 volts (battery positive voltage)?
- YES: Repair the combination meter. Check to see that all meters operate.
- NO: Go to Step 8.
- STEP 8. Check combination meter connector D-32 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
Q: Is combination meter connector D-32 in good condition?
- YES: Go to Step 9.
- NO: Repair or replace the damaged component(s). Refer to HARNESS CONNECTOR INSPECTION . Check to see that all meters operate.
- STEP 9. Check the wiring harness between combination meter connector D-32 (terminal 25 and 11) and ground.
Q: Is the wiring harness between combination meter connector D-32 (terminal 25 and 11) and ground in good condition?
- YES: There is no action to be taken.
- NO: Repair the wiring harness. Check to see that all meters operate.