LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2005 >> Montero >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> On-Vehicle Service >> Wave Pattern Check Using An Oscilloscope >> Standard Waveform
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Standard Waveform

STANDARD GENERATOR WAVEFORM

FUNCTION SPECIAL PATTERNS
Pattern height Variable
Variable knob Adjust while viewing the wave pattern
Pattern selector Raster
Engine revolutions Curb idle speed
Fig 1: Identifying Standard Generator Waveform
G02417461Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
NOTE: The voltage waveform of the generator "B" terminal can undulate as shown in Fig 2 . This waveform is produced when the regulator operates according to fluctuations in the generator load (current), and is normal for the generator.

If the ripple height is abnormally high (approximately 2 V or more during idling), the wires between the generator "B" terminal and the battery have broken due to fuse blowing, etc. The generator is usually operating properly  .

Fig 2: Identifying Normal Voltage Waveform Of Generator
G02417462Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.