Troubleshooting Guide

The charging system troubleshooting guide is shown in the following steps.

  1. STEP 1. 

    Q: Is the battery in good condition? (Refer to  BATTERY CHECK  .) 

    YES:  Go to Step 2.

    NO:  Charge or replace the battery.

  2. STEP 2. 

    Q: Is the generator drive belt in good condition? (Refer to  DRIVE BELT (FOR GENERATOR, WATER PUMP AND POWER STEERING OIL PUMP) (CHECK CONDITION)  .) 

    YES:  Go to Step 3.

    NO:  Adjust the belt tension or replace the belt.

  3. STEP 3. 

    Does the generator malfunction light turn on brightly when the ignition switch is turned to the "ON" position? 

    YES:  Go to Step 4.

    NO: 

    • Check the ignition switch. (Refer to INSPECTION .)
    • Check for burnt-out generator malfunction light bulb.
    • Check the generator. (Refer to INSPECTION  .)
    • Check the generator malfunction light-related circuits.
  4. STEP 4. 

    Q: Does the generator malfunction light go out after starting the engine? 

    YES:  Go to Step 5.

    NO:  Check the generator (Refer to INSPECTION  .)

  5. STEP 5. 

    Q: Is an oscilloscope available? 

    YES:  Go to Step 6.

    NO:  Go to  Step 7.

  6. STEP 6. 

    Q: Does the oscilloscope show a normal wave pattern? (Refer to  WAVE PATTERN CHECK USING AN OSCILLOSCOPE   .) 

    YES:  Go to Step 7.

    NO:  Check the generator. (Refer to INSPECTION  .)

  7. STEP 7. 
    • Engine: 2,500 r/min
    • Headlight: ON (high beam)
    • Voltage between generator "B" terminal and the positive battery terminal

      OK: 0.5 V or less

    • Voltage between the negative battery terminal and generator body

      OK: 0.5 V or less

    Q: Are the generator output line and ground line in good condition? 

    YES:  Go to Step 8.

    NO: 

    • Check the generator output line.
    • Check the generator ground line.
  8. STEP 8. 

    Q: Is the output current normal? (Refer to  OUTPUT CURRENT TEST   .) 

    YES:  Go to Step 9.

    NO:  Check the generator (Refer to INSPECTION  .)

  9. STEP 9. 

    Q: Is the regulated voltage normal? (Refer to Refer to  REGULATED VOLTAGE TEST   .) 

    YES:  Go to Step 10.

    NO:  Check the generator (Refer to INSPECTION  .)

  10. STEP 10. 

    Q: Are the voltage drops in the generator output line normal? (Refer to  GENERATOR OUTPUT LINE VOLTAGE DROP TEST   .) 

    YES:  Generator is normal. Check other systems.

    NO:  Check the output line.