LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2006 >> Lancer Evolution >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 12 (Cooling) >> On-Vehicle Service >> Fan Control Module Check
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Fan Control Module Check

WARNING: This page is about a different variant/trim than selected.
  1. Remove the fan control module connector.
  2. Turn the ignition switch to the "ON" position, and measure the voltage between the harness-side connector terminals.

    Standard value: Battery positive voltage 

    Fig 1: Measuring Voltage Between Harness-Side Connector Terminals
    G04271442Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  3. Connect the fan control module connector, and disconnect the condenser fan motor connector.
  4. Ensure that the A/C switch is off, and start the engine and run it at idle.
  5. Measure the voltage between the fan control module-side connector terminals.

    Standard value: 1 V or less 

  6. Turn the A/C switch to the "ON" position.
    WARNING: Stay clear of the fan when the fan starts running.
  7. Measure the voltage between the fan control module-side connector terminals while the fan is running. The voltage should repeat the values 1) and 2) below.

    Standard value: 

    1) 8.2+/-2.6 V 2) 

    2) Battery positive voltage+/-2.6 V 

  8. If the voltage does not repeatedly change as indicated, replace the fan control module.
    Fig 2: Measuring Voltage Between Fan Control Module-Side Connector Terminals
    G04271443Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.