Starter Relay Check < M/T >
WARNING: This page is about a different variant/trim than selected.
BATTERY VOLTAGE CONTINUITY TEST RESULTS
| BATTERY VOLTAGE |
TERMINAL NO. TO BE CONNECTED TO TESTER |
CONTINUITY TEST RESULTS |
| Not applied |
2 - 5 |
Less than 2 ohms |
| Connect terminal No.1 and battery (-) terminal. Connect terminal No.3 and battery (+) terminal. |
2 - 5 |
Open circuit |
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.