Troubleshooting Guide
The charging system troubleshooting guide is shown in the following steps.
- STEP 1.
Q: Is the battery in good condition? (Refer to Chassis Electrical - Battery - On-vehicle Service - BATTERY CHECK ).
YES : Go to Step 2.
NO : Charge or replace the battery.
- STEP 2.
Q: Is the generator drive belt in good condition? (Refer to General - Maintenance Service - DRIVE BELTS (FOR GENERATOR, POWER STEERING PUMP AND AIR CONDITIONING) (CHECK) ).
YES : Go to Step 3.
NO : Adjust the belt tension or replace the belt.
- STEP 3.
Q: Does the generator malfunction light come on when the ignition switch is turned on?
YES : Go to Step 4.
NO :
- Check the ignition switch. (Refer to Chassis Electrical Ignition Switch - Ignition Switch - INSPECTION .
- Check for burnt-out generator malfunction light.
- Check the generator. (Refer to Charging System - Generator Assembly INSPECTION .
- Check the generator malfunction light-related circuits.
- STEP 4.
Q: Does the generator malfunction light go out after starting the engine?
YES : Go to Step 5.
NO : Check the generator (Refer to Charging System - Generator Assembly - INSPECTION ).
- STEP 5.
Q: Is an oscilloscope available?
YES : Go to Step 6.
NO : Go to Step 7.
- STEP 6.
Q: Dose the oscilloscope show a normal wave pattern? (Refer to Charging System - On-vehicle Service - WAVE PATTERN CHECK USING AN OSCILLOSCOPE ).
YES : Go to Step 7.
NO : Check the generator. (Refer to Charging System - Generator Assembly - INSPECTION ).
- STEP 7.
- Engine: 2,500 r/min
- Headlight: ON (high beam)
- Voltage between generator terminal B and the positive battery terminal
OK: 0.5 V or less
- Voltage between the negative battery terminal and generator body
OK: 0.5 V or less
Q: Are the generator output line and ground line in good condition?
YES : Go to Step 8.
NO : Check the generator output line and ground line.
- STEP 8.
Q: Is the output current normal? (Refer to Charging System - On-vehicle Service - OUTPUT CURRENT TEST ).
YES : Go to Step 9.
NO : Check the generator (Refer to Charging System - Generator Assembly - INSPECTION ).
- STEP 9.
Q: Is the regulated voltage normal? (Refer to Charging System - On-vehicle Service - REGULATED VOLTAGE TEST ).
YES : Go to Step 10.
NO : Check the generator (Refer to Charging System - Generator Assembly - INSPECTION ).
- STEP 10.
Q: Is the voltage drop in the generator output line normal?
YES : Generator is normal. Check other systems.
NO : Check the output line.