Service Specifications

SERVICE SPECIFICATIONS

ITEMS STANDARD VALUE LIMIT
GENERATOR 
Regulated voltage
(Ambient temperature at voltage regulator)
-20°C (-4°F) 14.2-15.4 -
20°C (68°F) 13.9-14.9 -
60°C (140°F) 13.4-14.5 -
80°C (176°F) 13.1-14.2 -
Generator output line voltage drop (at 30A) V - Maximum 0.3
Output current - 70% of normal output current
Field coil resistance Ω Approximately 2-5 -
Brush protrusion length mm (in) - 2 (0.08)
STARTER MOTOR 
Free running characteristics Terminal voltage V 11 -
Current A 90 -
Speed r/min 2,000 or more -
Pinion gap mm (in) 0.5-2.0 (0.02-0.07) -
Commutator run-out mm (in) 0.05 (0.002) 0.1 (0.004)
Commutator diameter mm (in) 29.4 (1.16) Minimum 28.8 (1.13)
Undercut depth mm (in) 0.5 (0.02) Minimum 0.2 (0.008)-
IGNITION PARTS 
Spark plug gap mm (in) 0.7-0.8 (0.028-0.031) 1.2 (0.047)