Body & Frame: Windows: Door
- Specifications
- General Information
- Central Door Locking System Diagnosis
- Troubleshooting Strategy
- Trouble Symptom Chart < Central Door Locking System >
- Input Signal Chart < Central Door Locking System >
- Symptom Procedures
- INSPECTION PROCEDURE A-1: Central Door Locking System does not Work at All
- INSPECTION PROCEDURE A-2: A Door or A Liftgate cannot be Locked or Unlocked by The Central Door Locking System
- INSPECTION PROCEDURE A-3: The Liftgate does not Open
- INSPECTION PROCEDURE A-4: Selector "P" Position-linked Door Unlock Function does not Operate
- Input Signal Procedures
- Power Window Diagnosis
- Troubleshooting Strategy
- Diagnostic Trouble Code Chart Power Window
- Trouble Symptom Chart < Power Window >
- Diagnostic Trouble Code Procedures
- CODE NO. L0730 P/W (DR) SW pulse 1 disconnection
- CODE NO. L0732 P/W (DR) SW pulse 2 disconnection
- CODE NO. L0734 P/W (DR) Above window position
- CODE NO. L0736 P/W (DR) Sensor fail (ground)
- CODE NO. L0740 P/W (DR) 3 times jam - protection
- CODE NO. L0746 P/W (DR) Parameter read fail; CODE NO. L0750 P/W (DR) Position read fail
- Symptom Procedures
- INSPECTION PROCEDURE C-1: Power Windows do not Work at All
- INSPECTION PROCEDURE C-2: Driver's Power Window does not Work by means of The Power Window Main Switch
- INSPECTION PROCEDURE C-3: Relevant Power Window(s) does not Work by means of The Front and Rear Passenger's Power Window Sub Switches
- INSPECTION PROCEDURE C-4: Front and/or Rear Passenger's Power Window(s) do not Work by means of The Power Window Main Switch
- INSPECTION PROCEDURE C-5: The Power Window Timer Function does not Work Normally
- INSPECTION PROCEDURE C-6: Power Window Anti-trap Function does not Work Normally < Driver's Side Only >
- INSPECTION PROCEDURE C-7: The Window Glass Lowers Automatically while it is Rising < Driver's Side Only >
- Check At Ecu Terminal
- Door Diagnosis
- Introduction To Glass And Door Diagnosis
- Glass And Door Diagnostic Troubleshooting Strategy
- Symptom Chart
- Symptom Procedures
- INSPECTION PROCEDURE 1: Water Leak Through Door Window Glass
- INSPECTION PROCEDURE 2: Door Window Glass Malfunction
- INSPECTION PROCEDURE 3: Water Leak Through Door Edge
- INSPECTION PROCEDURE 4: Water Leak from Door Center
- INSPECTION PROCEDURE 5: Door Hard to Open
- INSPECTION PROCEDURE 6: Door does not Open or Close Completely
- INSPECTION PROCEDURE 7: Uneven Gap Between Body
- INSPECTION PROCEDURE 8: Wind Noise Around Door
- How To Locate Wind Noise
- Special Tools
- On-Vehicle Service
- Front Door Fit Adjustment
- Door Window Glass Adjustment
- Power Window Check
- Adjustment Of Faulty Power Window
- POWER WINDOW SAFETY MECHANISM CHECK < Driver's side only >
- Power Window Timer Function Check
- Power Window Operation Current Check
- Learning Procedures Of The Power Window Fully Closed Position
- Central Door Locking System Check
- Key-In Prevention Function Check
- Selector "P" Position-Linked Door Unlocking Function Check
- Door Outside Handle Assembly Play Check
- Door Inside Handle Check
- Customize Function
- Door Assembly
- Door Glass And Regulator
- Door Handle And Latch
- Window Glass RUNCHANNEL And Door Opening Weatherstrip