Service Specifications
SERVICE SPECIFICATIONS (2.4L & 3.8L)
| ITEMS | STANDARD VALUE | LIMIT | |
|---|---|---|---|
| Regulated voltage (Ambient temperature at voltage regulator) |
- 20°C (- 4°F) | 14.2-15.4 | - |
| 20°C (68°F) | 13.9-14.9 | - | |
| 60°C (140°F) | 13.4-14.6 | - | |
| 80°C (176°F) | 13.1-14.5 | - | |
| Generator output line voltage drop (at 30 A) V | - | Maximum 0.3 | |
| Output current | - | 70 % of normal output current | |
| Field coil resistance Ω | Approximately 2-5 | - | |
| Brush protrusion length mm (in) | - | Minimum 2 (0.08) | |