Resistance Measurement Between Electronic Control Coupling Solenoid Connector Terminals

Disconnect the D-119 connector, and measure the resistance value between the connector terminals on the electronic control coupling side. If the measured resistance value is out of the standard value range, replace the electronic control coupling. Refer to ELECTRONIC CONTROL COUPLING .

Standard value: 2.2-4.0 ohm 

Fig 1: Identifying Electronic Control Coupling
G05432265Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.