Nominal Resistance Of The Fuel Level Sensor
WARNING: This page is about a different variant/trim than selected.
- Remove the fuel pump module (Refer to FUEL TANK ).
- When float of the fuel level sensor is in stopper positions F and E, ensure that resistance between the fuel level sensor terminal and ground terminal is within the standard value.
Standard value:
FLOAT POSITION CHARTFloat position Gauge resistance value (ohms) Main Sub Stopper position "F" 6.5 ± 1.0 6.5 ± 1.0 Stopper position "E" 41.9 ± 1.0 78.1 ± 1.0 - When the float is moved slowly between stopper positions "F" and "E", ensure that the resistance is smoothly changing.